Skip Navigation
Skip to contents

Ann Coloproctol : Annals of Coloproctology

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Coloproctol > Volume 42(4); 2026 > Article
Original Article
Colorectal cancer
Linear versus circular stapler for colorectal anastomosis in laparoscopic sigmoidectomy: a retrospective comparative study
Hiep Van Pham1orcid, Thang Manh Tran2orcid, Phuong Nguyen Nhu Pham2orcid
Annals of Coloproctology 2026;42(4):468-477.
DOI: https://doi.org/10.3393/ac.2025.01242.0177
Published online: August 26, 2026

1Department of Digestive Surgery, 108 Military Central Hospital, Hanoi, Vietnam

2College of Health Sciences, VinUniversity, Hanoi, Vietnam

Correspondence to: Thang Manh Tran, MD College of Health Sciences, VinUniversity, Hanoi 100000, Vietnam Email: thangtranmanh96@gmail.com
• Received: October 17, 2025   • Revised: April 27, 2026   • Accepted: June 22, 2026

© 2026 The Korean Society of Coloproctology

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

prev next
  • 4,516 Views
  • 65 Download
  • Purpose
    The choice between linear side-to-side and circular end-to-end staplers for colorectal anastomosis after laparoscopic sigmoidectomy remains a topic of debate. This study compared intraoperative efficiency, postoperative recovery, complications, and quality of life (QoL) between the 2 techniques.
  • Methods
    This retrospective cohort study included 83 patients who underwent elective laparoscopic sigmoidectomy for sigmoid cancer at a single center between January 2023 and August 2024. Patients were grouped according to the stapling technique used for anastomosis (linear stapler, n=23; circular stapler, n=60). Intraoperative characteristics, including operative time and stapler use; postoperative outcomes, including length of hospital stay and complications; and longitudinal QoL, assessed using the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire–Colorectal Cancer (QLQ-CR29) questionnaire at 1, 3, 6, 9, and 12 months, were analyzed.
  • Results
    Baseline characteristics were comparable between groups. Operative time did not differ significantly between the linear and circular stapler groups (90.73±14.02 minutes vs. 94.63±13.65 minutes, P=0.25). The linear stapler group required more staplers overall (3.04±0.82 vs. 1.53±0.72, P<0.001) but had a shorter hospital stay (10.09±1.83 days vs. 11.70±3.62 days, P=0.04). Oncologic outcomes and complication rates were low and comparable (anastomotic leakage: 4.3% vs. 0%, P=0.277). At 12 months, QoL scores did not differ significantly between groups, although descriptive trends suggested faster recovery of bowel function and abdominal pain in the linear stapler group during the first 6 months.
  • Conclusion
    In this single-center retrospective series, both linear side-to-side and circular end-to-end stapling techniques appeared safe, feasible, and clinically acceptable. Circular stapling required fewer stapling devices intraoperatively, whereas linear stapling was associated with modestly shorter hospitalization and descriptively faster early functional recovery. These findings are hypothesis-generating and warrant prospective validation in larger, balanced cohorts to guide patient- and technique-specific surgical decision-making.
Colorectal cancer is a leading cause of morbidity and mortality worldwide, and sigmoid colon tumors account for a substantial proportion of cases [1]. Laparoscopic sigmoidectomy is considered the standard approach for resectable sigmoid colon cancer because it is associated with less postoperative pain, shorter hospitalization, and long-term oncologic outcomes comparable to those of open surgery [2, 3]. A critical step in this procedure is colorectal anastomosis, which can influence postoperative complications, including leakage, stenosis, and bleeding [4].
The choice of stapling device—linear staplers for side-to-side anastomosis or circular staplers for end-to-end anastomosis—remains clinically important. Linear staplers may create a larger anastomotic lumen and thereby reduce the risk of stenosis [5], whereas circular staplers provide uniform compression and remain the traditional approach for colorectal anastomosis [6]. Previous studies have compared these devices in gastrectomy [7], but evidence specific to laparoscopic sigmoidectomy remains limited, particularly evidence incorporating long-term patient-reported quality of life (QoL). Additional high-quality data comparing intraoperative efficiency, recovery profiles, and QoL after linear versus circular anastomosis in laparoscopic sigmoidectomy are needed to inform surgical decision-making.
This study addressed that knowledge gap by retrospectively comparing linear and circular stapling techniques in laparoscopic sigmoidectomy for cancer. Intraoperative metrics, postoperative outcomes, and longitudinal QoL up to 12 months were evaluated. We hypothesized that overall safety and oncologic efficacy would be similar between techniques but that the anastomotic technique could differentially affect resource utilization and early postoperative functional recovery.
Ethics statement
This study was approved by the Institutional Review Board of 108 Military Central Hospital (No. IRB-2023-015). The requirement for informed consent was waived because of the retrospective design and use of anonymized data. The study followed the principles of the Declaration of Helsinki.
Study design and patients
We conducted a single-center retrospective cohort study in the Department of Digestive Surgery at 108 Military Central Hospital, Hanoi, Vietnam. Consecutive patients treated between January 2023 and August 2024 were included.
Adult patients aged 18 years or older with histologically confirmed sigmoid colon cancer who underwent elective laparoscopic sigmoidectomy with primary colorectal anastomosis were included. Patients were grouped according to anastomosis type: linear stapler or circular stapler. The exclusion criteria were emergency surgery, conversion to open surgery, synchronous colorectal tumors requiring extended resection, metastatic disease precluding curative-intent surgery, and incomplete clinical records. Group allocation was not randomized; the anastomotic technique was selected by the operating surgeon according to intraoperative findings and surgeon preference.
Surgical procedures
All operations were performed by experienced colorectal surgeons using standardized laparoscopic techniques under general anesthesia. Patients were placed in the modified lithotomy position, defined as the supine position with the legs spread at 45°, to facilitate pelvic access. Pneumoperitoneum was established at 12 mmHg, followed by placement of 4 trocars. Systematic intraoperative exploration was performed to assess tumor location, depth of invasion, and the presence of peritoneal or hepatic metastases.
Dissection began with the assistant elevating the sigmoid colon and retracting the small bowel cephalad to expose the inferior mesenteric artery (IMA). Lymphadenectomy followed oncologic principles, with D2 or D3 dissection performed according to tumor stage. High ligation of the IMA was deliberately avoided to preserve autonomic nerve function. Instead, the IMA was preserved at its origin, with selective lymph node dissection at the IMA root and selective ligation of the sigmoid arteries. The sigmoid and descending colon were fully mobilized, including splenic flexure release when needed, to achieve a tension-free anastomosis. The sigmoid colon was transected approximately 7 cm proximal and distal to the tumor using 2 Endo GIA 60-mm linear staplers (Medtronic) with vascular or universal cartridges.
For the linear stapler group, the proximal colon stump was opened, and a side-to-side, functional end-to-end colorectal anastomosis was created intracorporeally using an Endo GIA 60-mm stapler inserted through aligned enterotomies (Fig. 1). The common enterotomy was closed in a single layer with a continuous 3-0 Vicryl suture (Ethicon). The specimen was extracted through a 4- to 5-cm suprapubic Pfannenstiel incision protected with a wound retractor.
For the circular stapler group, the umbilical port incision was extended to 3–4 cm for extracorporeal specimen extraction and proximal colon transection. The anvil of a 28-mm EEA circular stapler (Medtronic) was secured to the proximal colon stump with a purse-string suture. During the study period, a 28-mm circular stapler was routinely used as the standard device in our department. This size was considered suitable for most patients, and intraoperative assessment was performed to ensure safe transanal introduction without excessive tension. The stapler shaft was then introduced transanally, and a laparoscopically guided end-to-end anastomosis was performed.
In both groups, air-leak testing was performed by insufflating the rectum with air while the anastomosis was immersed in saline to confirm integrity.
Outcome measures
Data were extracted from medical records, operative reports, pathology reports, and follow-up clinic notes by 2 independent reviewers; discrepancies were resolved by consensus. Variables were categorized as patient characteristics, intraoperative characteristics, postoperative outcomes, and complications. Complications were assessed within 30 days postoperatively and included anastomotic bleeding, stenosis, leakage diagnosed clinically or radiologically, wound infection, and low anterior resection syndrome (LARS) [8]. Anastomotic leakage was diagnosed clinically and/or radiologically. Anastomotic stenosis was defined as endoscopic or radiological evidence of narrowing at the anastomosis, including inability to pass a standard adult colonoscope through the anastomosis at follow-up endoscopy, with or without obstructive symptoms [9]. Complications were graded using the Clavien-Dindo classification [10].
QoL was evaluated using the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire–Colorectal Cancer (QLQ-CR29) questionnaire [11], a validated 29-item tool that assesses colorectal cancer–specific symptoms across domains including bowel function, urinary symptoms, pain, and psychosocial aspects. Assessments were conducted preoperatively at baseline and postoperatively at 1, 3, 6, 9, and 12 months through in-person or telephone interviews. Responses to each item were recorded on the standard 4-point Likert scale (1, not at all; 4, very much). Raw item scores are presented throughout, without linear transformation to the 0–100 scale, and higher scores indicate worse symptoms in most domains. Because a formal LARS score was not prospectively collected, postoperative bowel dysfunction was described using follow-up clinical documentation and relevant QoL symptom domains.
Statistical analysis
Data were analyzed using IBM SPSS ver. 27.0 (IBM Corp). Continuous variables are presented as mean±standard deviation or median with interquartile range (IQR), according to normality assessed using the Shapiro-Wilk test. Between-group comparisons used the t-test or Mann-Whitney U-test for continuous variables and the chi-square test or Fisher exact test for categorical variables; Fisher exact test was used for variables with expected frequencies less than 5 to improve accuracy for rare events. For QoL outcomes, the Mann-Whitney U-test was used to evaluate 12-month differences, with effect sizes calculated as r=Z / √N. Because of the retrospective nonrandomized design, small sample size, group imbalance, and limited number of events, propensity score matching was not performed, and no robust multivariable model for rare complications was prespecified. Therefore, all analyses should be considered exploratory. A 2-sided P-value of <0.05 was considered statistically significant. Missing data (<5%) were handled by listwise deletion.
Patient characteristics
A total of 83 patients met the inclusion criteria: 23 in the linear stapler group and 60 in the circular stapler group. Baseline demographic and clinical characteristics were generally well matched between groups (Table 1).
All tumors were located in the sigmoid colon region, with no significant between-group differences in tumor distance from the anal verge (25.87±2.78 cm vs. 23.28±5.15 cm, P=0.53) or mean tumor size (27.59±20.96 mm vs. 31.03±20.6 mm, P=0.61). Most tumors in both groups were pT3–pT4 (91.3% vs. 85.0%, P=0.719), indicating locally advanced disease, and the distribution was comparable between groups. One patient in the circular stapler group had undergone temporary sigmoid colostomy 1 month before resection for proximal diversion, but no patient underwent prophylactic diverting stoma creation at the time of definitive surgery.
Intraoperative characteristics
Intraoperative findings are summarized in Table 2. Operative time and intraoperative blood loss were comparable between groups. The linear stapler group required significantly more staplers overall than the circular stapler group (3.04±0.82 vs. 1.53±0.72, P<0.001) and more staplers for distal rectal transection (2.28±0.96 vs. 1.31±0.61, P<0.001). No anastomosis-related intraoperative complications, including intraoperative staple-line failure or bleeding, occurred in either group.
Postoperative outcomes
Key postoperative outcomes are presented in Table 3. Oncologic parameters were comparable between techniques. The proportion of pT3–pT4 tumors was similar between the linear and circular stapler groups (91.3% vs. 85.0%, P=0.719). Lymph node yield also did not differ significantly between groups (7.45±2.96 vs. 8.65±4.92, P=0.31). Recovery milestones were comparable, but length of hospital stay was longer in the circular stapler group than in the linear stapler group (10.09±1.83 days vs. 11.7±3.62 days, P=0.04).
Complications
Postoperative complications were uncommon in this cohort, and overall complication rates did not differ significantly between techniques (Table 4). No anastomotic leaks occurred in the circular stapler group, whereas 1 anastomotic leak occurred in the linear stapler group and was managed conservatively. Anastomotic bleeding requiring intervention was also rare, occurring in 1 patient in the linear stapler group and no patients in the circular stapler group. Two patients in the circular stapler group developed anastomotic stenosis, whereas none in the linear stapler group did. Both were detected at surveillance endoscopy, were mild and asymptomatic, and were managed conservatively.
Three patients in the circular stapler group experienced postoperative LARS symptoms, including clustered stooling and urgency, compared with no patients in the linear stapler group, although the difference was not statistically significant. Tumor distances from the anal verge in these 3 patients were 19, 20, and 24 cm, suggesting that relatively distal tumor location may have contributed to postoperative bowel dysfunction.
Quality of life
Health-related QoL was assessed longitudinally across 18 domains using the EORTC QLQ-CR29 questionnaire. Periodic changes are shown in Fig. 2 as descriptive trajectories without formal statistical comparison at intermediate time points. This figure emphasizes the domains with the most clinically relevant descriptive early differences, particularly stool frequency, bowel control–related symptoms, and abdominal pain, while the complete 12-month domain-by-domain comparison is presented in Table 5. In the bowel function domain, stool frequency improved more rapidly in the linear stapler group and returned to baseline by 6 months, whereas recovery was slower in the circular stapler group. Fecal incontinence worsened transiently at 3 to 6 months, with more pronounced worsening in the circular stapler group. Blood and mucus in stool decreased steadily in both groups. Flatulence peaked at 6 to 9 months but was lower in the circular stapler group. Embarrassment related to defecation normalized earlier in the linear stapler group.
In the pain and physical symptom domains, abdominal pain declined sharply in the linear stapler group and normalized by 6 months, whereas it declined more gradually in the circular stapler group and remained elevated at 12 months. Buttock pain was minimal in both groups. Bloated feeling fluctuated more in the circular stapler group.
Urinary symptoms showed persistently higher urinary frequency in the circular stapler group, stable urinary incontinence in the linear stapler group, and mild fluctuations in urinary incontinence in the circular stapler group. Dysuria remained near baseline in both groups.
In the systemic and psychosocial domains, anxiety improved earlier in the linear stapler group. Weight concerns and body image returned to baseline by 12 months in both groups. Hair loss and dry mouth increased slightly postoperatively, more so in the circular stapler group, with partial recovery over time. Trouble with taste peaked at the midterm assessment in both groups.
At 12 months, no statistically significant between-group differences were found across domains (all P>0.05, effect sizes r<0.2), as shown in Table 5. Median scores and IQRs were similar, indicating minimal long-term practical differences between techniques.
This retrospective study demonstrated that linear and circular stapling techniques for laparoscopic sigmoidectomy were both safe and associated with comparable oncologic outcomes and complication rates. These results are consistent with earlier systematic reviews and meta-analyses reporting no major differences in leakage or mortality between stapled anastomotic configurations [12]. However, the findings should be interpreted cautiously because the analysis was retrospective and nonrandomized and included a small, imbalanced sample of 23 versus 60 patients, with likely surgeon-selection effects and incomplete comorbidity data. Robust propensity score methods or multivariable adjustment would not be expected to reliably eliminate confounding in a dataset of this size. Accordingly, these results should be considered hypothesis-generating rather than definitive.
A major finding of this study was the difference in intraoperative resource utilization. As expected, the circular anastomosis technique required significantly fewer linear stapler cartridges than the linear side-to-side technique. In this series, the circular stapler group typically required one linear stapler firing for rectal transection plus the circular stapling device itself, whereas the linear stapler group required one or more cartridges for rectal transection plus at least one further cartridge for the intracorporeal anastomosis. This reduction in disposable stapler use could translate into lower device costs, although the economic implications should be interpreted alongside downstream clinical recovery rather than cartridge counts alone.
Notably, postoperative hospitalization was approximately 1 to 2 days longer in the circular stapler group than in the linear stapler group in this study (11.7 days vs. 10.1 days, P=0.04). This finding, however, should be interpreted cautiously. Given the retrospective, nonrandomized design and group imbalances, the circular stapler cohort was marginally older and had a higher prevalence of diabetes. These baseline comorbidities may have contributed to delayed functional recovery and prolonged hospitalization independently of anastomotic technique. Although no single postoperative complication was significantly more frequent in the circular stapler group, anastomotic stenosis and LARS-like symptoms occurred only in that group (3.3% and 5.0%, respectively), suggesting possible subtle differences in functional recovery. Nevertheless, the number of events was very small, and the study was underpowered to determine whether these findings represent true device-related effects. Accordingly, the difference in length of stay should be interpreted as an association rather than evidence of an independent causal effect of stapling technique. From a practical standpoint, even a modest increase in hospitalization could offset any upfront reduction in stapler cartridge use, although formal cost-effectiveness analysis would be required to confirm this. Importantly, the 3 LARS cases in the circular stapler group occurred in patients with tumor distances of 19, 20, and 24 cm from the anal verge. Because bowel dysfunction after colorectal resection is strongly influenced by the level of the anastomosis [13], the observed LARS cases should not be attributed solely to stapling technique, and distal tumor location may have been an important contributing factor.
Surgical technique was standardized as much as possible between groups to isolate the effect of anastomosis type. At our center, low ligation with preservation of the IMA was the standardized approach for sigmoidectomy during the study period. This strategy was adopted to preserve perfusion to the proximal colon and reduce the risk of anastomotic tension and ischemia while still permitting central lymph node dissection when indicated. This institutional practice is consistent with prior evidence suggesting that low ligation is oncologically safe [14–16]. Although standardized D2 or D3 lymphadenectomy was performed intraoperatively by the surgical team, the overall mean lymph node yield was modestly lower than the widely recommended threshold of 12 nodes. This discrepancy is likely attributable to institutional variation in ex vivo pathological grossing and manual nodal harvesting techniques rather than incomplete surgical resection. Importantly, the proportion of positive nodes, reflected by pN category, was comparable between groups, supporting oncologic comparability for the purpose of this comparison. Therefore, outcome differences are unlikely to be explained by surgical confounders such as the extent of lymphadenectomy or blood supply, because these factors were standardized. Instead, differences in functional recovery may be more plausibly related to anastomotic configuration and resulting luminal geometry. A linear stapler creates a broad side-to-side anastomotic lumen, which may reduce the risk of narrowing and provide greater pliability as the bowel adapts. By contrast, a circular stapler creates a ring-shaped end-to-end anastomosis that may be narrower or more prone to scar contraction, potentially resulting in a smaller-caliber lumen. This mechanical difference may explain the trend toward fewer strictures and faster bowel function recovery in the linear stapler group. The wider anastomotic lumen created by the linear technique may facilitate earlier stool passage and better rectal reservoir function, thereby accelerating the return of normal bowel habits. In contrast, the circular anastomosis creates a smaller cross-sectional ring that may initially restrict stool passage or compliance, contributing to symptoms such as frequency, urgency, and possibly LARS in some patients. The QoL data support these hypotheses: patients who underwent linear anastomosis reported quicker improvement in stool frequency and less long-term abdominal pain. These findings are consistent with prior studies in gastrointestinal surgery. However, prior literature provides only indirect support for the hypothesis that anastomotic configuration can influence postoperative bowel function and QoL. In a randomized controlled trial of 74 patients with nonemergent sigmoid and rectal cancers, Habeeb et al. [17] compared side-to-end and end-to-end colorectal anastomoses and found no significant difference in anastomotic leakage rates (13.5% vs. 8.1%, P=0.47) or overall postoperative complications. However, the side-to-end group showed more favorable functional recovery: bowel frequency changed significantly only in the end-to-end group (P=0.04), flatus incontinence differed significantly in the side-to-end group (P<0.001), and liquid stool incontinence and stool clustering improved over time in both groups. Their QoL analysis also suggested more complete recovery of physical and functional well-being in the side-to-end group during follow-up. It should be noted that Habeeb et al. [17] compared a side-to-end (Baker type) colorectal anastomosis, in which the colonic end is anastomosed to the side of the rectal stump, rather than the intracorporeal side-to-side (functional end-to-end) configuration used in the present study. The 2 techniques are not interchangeable, but they share the mechanical principle of creating a wider and more compliant anastomotic lumen with a short blind reservoir, in contrast to the narrower circular end-to-end ring. Their findings are therefore mechanistically relevant to, but not directly confirmatory of, our observations, and should be regarded as indirect supporting evidence only. In a different but mechanistically relevant setting, Wei et al. [18] compared linear and circular stapling in esophagojejunostomy after laparoscopic total gastrectomy and reported a lower anastomotic stenosis rate with linear stapling (0% vs. 7.1%) and less intraoperative blood loss, whereas reflux-related outcomes did not differ significantly between groups. They also observed lower postoperative constipation and dysphagia scores in the linear stapler group at 12 months. Although these findings are not directly comparable to colorectal sigmoidectomy, together they support the plausibility that stapling configuration may affect early functional recovery and anastomotic caliber more than long-term patient-reported outcomes. The present results are consistent with these findings and suggest that side-to-side linear anastomosis may offer better short-term functional outcomes without compromising long-term results.
Despite differences in early recovery trajectories, the 2 groups were nearly indistinguishable in QoL by 12 months after surgery. No significant long-term QoL deficits were associated with either technique, and patients generally returned to baseline functional status by 12 months. These findings suggest that anastomosis type may influence the speed of functional recovery but does not appear to affect overall recovery at 12 months. In other words, linear stapling may accelerate the return of normal bowel function and reduce pain during the early postoperative months, whereas outcomes in the circular stapler group appeared to converge with those in the linear stapler group by 12 months. From a clinical standpoint, earlier functional recovery may improve patient comfort, facilitate return to work or daily activities, and reduce interim healthcare use, such as symptom-related clinic visits. For example, the sharper decline in abdominal pain by 6 months in the linear stapler group could indicate less reliance on analgesics and a smoother rehabilitation course. Similarly, resolution of bowel habit changes by 3 to 6 months rather than 9 to 12 months may improve QoL during the early postoperative period. Thus, even if long-term QoL is equivalent, the short-term QoL and functional benefits observed with linear stapling may be clinically relevant. These findings support consideration of linear anastomosis, particularly in patients for whom early recovery of bowel function is a priority. Comparative studies have similarly reported advantages in short-term QoL and recovery with linear staplers in digestive tract reconstruction [7, 18].
Limitations
This study should be interpreted in light of several limitations. First, this was a retrospective, single-center analysis, which introduces potential selection bias and limits generalizability. The anastomotic technique was not randomized, and the group sizes were imbalanced (n=23 vs. n=60), making rare event comparisons particularly unstable. Second, surgeon preference and technical judgment likely influenced stapler selection, and surgeon-level allocation may therefore have confounded the observed associations. Third, a standardized Charlson Comorbidity Index was not available for all patients and could not be reconstructed reliably from the retrospective records, limiting adjustment for baseline health status. Fourth, the sample size was too small for robust propensity score matching and too sparse for dependable multivariable modeling of uncommon complications; consequently, the current analyses are exploratory and hypothesis-generating. Fifth, all circular anastomoses were performed using a 28-mm stapler, reflecting standardized institutional practice during the study period rather than patient-specific stapler diameter selection. Although a smaller circular stapler could theoretically result in a narrower anastomotic lumen and thereby increase the risk of benign stricture, existing colorectal literature does not consistently demonstrate a clear relationship between stapler diameter and anastomotic stenosis [19]. In this cohort, 2 cases of mild anastomotic stenosis occurred in the circular stapler group; however, both were asymptomatic and managed conservatively. Given the uniform use of a single stapler size and the small number of events, these data do not allow meaningful assessment of the effect of stapler diameter on stricture formation. This factor should therefore be interpreted cautiously, and future studies comparing different stapler sizes in a controlled manner are warranted. In addition, QLQ-CR29 results are reported as raw item scores rather than as linearly transformed 0–100 scale scores, which limits direct numerical comparison with studies that report standardised scores. Finally, although QoL follow-up was relatively complete through 12 months, longer-term functional differences were not captured.
Conclusions
Both linear and circular stapling techniques for laparoscopic sigmoidectomy appeared clinically acceptable in this retrospective single-center cohort. Linear stapling was associated with descriptively faster early functional recovery and shorter hospitalization, whereas circular stapling required fewer stapling devices. Because the comparison was nonrandomized and limited by small sample size, group imbalance, and residual confounding, these observations should be interpreted as hypothesis-generating. Larger prospective multicenter studies incorporating surgeon-level adjustment, standardized comorbidity assessment, and formal functional outcome measures are needed.

Conflict of interest

No potential conflict of interest relevant to this article was reported.

Funding

None.

Author contributions

Conceptualization: HVP; Data curation: TMT, PNNP; Formal analysis: HVP; Investigation: HVP; Methodology: TMT, PNNP; Project administration: HVP; Visualization: TMT, PNNP; Writing–original draft: HVP, TMT; Writing–review & editing: PNNP. All authors read and approved the final manuscript.

Fig. 1.
Step-by-step creation of an intracorporeal colorectal anastomosis using a linear stapler. (A) The proximal colon and rectal stump are aligned with an anchoring suture, and enterotomies are made on both sides. (B) An Endo GIA 60-mm linear stapler (Medtronic) is inserted through the enterotomies to create a side-to-side colorectal anastomosis. (C) The common enterotomy is closed with a continuous 3-0 Vicryl suture (Ethicon). (D) Anastomotic integrity is assessed by checking for air or fluid leakage.
ac-2025-01242-0177f1.jpg
Fig. 2.
Postoperative health-related quality of life (QoL) trajectories in the linear and circular stapler groups. The graph shows periodic changes in symptom scores across domains of the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire–Colorectal Cancer (QLQ-CR29) questionnaire during the 12 months after surgery. Values are raw item scores on the 4-point Likert response scale (1, not at all; 4, very much). Higher scores indicate worse symptoms. Both groups showed initial postoperative worsening in QoL at 3 months, followed by improvement by 12 months. The linear stapler group showed faster recovery in selected domains, particularly bowel function and pain, than the circular stapler group during the early postoperative period. By 12 months, scores had converged between groups, with no significant difference in any QoL domain. (A) Abdominal pain. (B) Bloated feeling. (C) Blood and mucus in stool. (D) Stool frequency. (E) Fecal incontinence. (F) Embarrassed by defecation pattern. POM, postoperative month.
ac-2025-01242-0177f2.jpg
ac-2025-01242-0177f3.jpg
Table 1.
Patient characteristics (n=83)
Characteristic Linear stapler (n=23) Circular stapler (n=60) P-value
Age (yr) 64.57±13.09 67.68±12.83 0.320
Sex 0.792
 Male 15 (65.2) 42 (70.0)
 Female 8 (34.8) 18 (30.0)
Body mass index (kg/m2) 21.23±2.25 21.56±1.87 0.870
Comorbidity
 Diabetes 2 (8.7) 16 (26.7) 0.134
 Hypertension 8 (34.8) 20 (33.3) 0.901
ASA physical status >0.999
 I 9 (39.1) 23 (38.3)
 II 11 (47.8) 27 (45.0)
 III 3 (13.1) 10 (16.7)
Prior temporary colostomy 0 (0) 1 (1.7) >0.999
Tumor distance from AV (cm) 25.87±2.78 23.28±5.15 0.530
Tumor size (mm) 27.59±20.96 31.03±20.60 0.610

Values are presented as mean±standard deviation or number (%).

ASA, American Society of Anesthesiologists; AV, anal verge.

Table 2.
Intraoperative characteristics (n=83)
Characteristic Linear stapler (n=23) Circular stapler (n=60) P-value
Operative time (min) 90.73±14.02 94.63±13.65 0.250
Operative blood loss (mL) 25 (15–40) 20 (15–30) 0.410
Total No. of stapler cartridges used 3.04±0.82 1.53±0.72 <0.001
No. of staplers for distal rectal transection 2.28±0.96 1.31±0.61 <0.001
Cases by surgeons 0.953
 Surgeon 1 10 (43.5) 26 (43.3)
 Surgeon 2 7 (30.4) 20 (33.3)
 Surgeon 3 6 (26.1) 14 (23.3)

Values are presented as mean±standard deviation, median (interquartile range), or number (%).

Table 3.
Postoperative pathological and recovery outcomes (n=83)
Outcome Linear stapler (n=23) Circular stapler (n=60) P-value
Advanced tumor stage (pT3–pT4) 21 (91.3) 51 (85.0) 0.719
No. of lymph nodes harvested 7.45±2.96 8.65±4.92 0.310
Lymph node staginga >0.999
 pN0 17 (73.9) 44 (74.6)
 pN1 4 (17.4) 10 (16.9)
 pN2 2 (8.7) 5 (8.5)
Time to first flatus (day) 3.47±1.4 3.67±1.4 0.630
Time to oral diet resumption (day) 4.32±1.49 3.93±1.73 0.350
Length of hospital stay (day) 10.09±1.83 11.70±3.62 0.040

Values are presented as number (%) or mean±standard deviation.

aOne missing case excluded in the circular stapler group.

Table 4.
Postoperative complications within 30 days (n=83)
Complication Linear stapler (n=23) Circular stapler (n=60) P-value
Anastomotic leak 1 (4.3) 0 (0) 0.277
Anastomotic bleeding 1 (4.3) 0 (0) 0.277
Anastomotic stenosis 0 (0) 2 (3.3) >0.999
Wound infection 0 (0) 1 (1.7) >0.999
LARS 0 (0) 3 (5.0) 0.557
Clavien-Dindo classificationa 0.413
 I 1 0
 II 1 2

Values are presented as number (%) or number only. P-values were calculated using the 2-tailed Fisher exact test.

LARS, low anterior resection syndrome.

aNo severe complications (grade III–V) occurred in either cohort.

Table 5.
Quality of life at 12 months after laparoscopic sigmoidectomy
Domain Linear stapler Circular stapler U Z P-value Effect size (r)
Urinary frequency 2 (2–3) 2 (2–4) 67.5 –0.45 0.622 0.09
Urinary incontinence 1 (1–1) 1 (1–1) 72.0 –0.21 0.570 0.04
Dysuria 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
Abdominal pain 1 (1–1) 1 (1–1) 68.0 –0.42 0.380 0.08
Buttock pain 1 (1–1) 1 (1–1) 68.0 –0.42 0.380 0.08
Bloated feeling 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
Blood and mucus in stool 2 (2–2) 2 (2–2) 81.5 0.29 0.559 0.06
Dry mouth 1 (1–1) 1 (1–1.5) 64.5 –0.61 0.421 0.12
Hair loss 1 (1–1) 1 (1–1) 69.5 –0.35 0.636 0.07
Trouble with taste 1 (1–1.2) 1 (1–2) 69.0 –0.37 0.666 0.07
Anxiety 1 (1–1.2) 1 (1–1.5) 72.0 –0.21 0.809 0.04
Weight concerns 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
Body image 3 (3–3) 3 (3–3) 72.0 –0.21 0.570 0.04
Flatulence 1 (1–2) 1 (1–1.5) 83.0 0.37 0.665 0.07
Fecal incontinence 1 (1–1) 1 (1–1) 72.0 –0.21 0.570 0.04
Sore skin around anus 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
Stool frequency 2 (2–2) 2 (2–2) 72.0 –0.21 0.570 0.04
Embarrassed by defecation pattern 1 (1–1) 1 (1–1) 72.0 –0.21 0.570 0.04

Values are presented as median (interquartile range). Values are raw item scores on the 4-point Likert response scale (1 = not at all to 4 = very much); higher scores indicate worse symptoms in most domains.

  • 1. Bray F, Laversanne M, Sung H, Ferlay J, Siegel RL, Soerjomataram I, et al. Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2024;74:229–63. ArticlePubMed
  • 2. Veldkamp R, Kuhry E, Hop WC, Jeekel J, Kazemier G, Bonjer HJ, et al. Laparoscopic surgery versus open surgery for colon cancer: short-term outcomes of a randomised trial. Lancet Oncol 2005;6:477–84. ArticlePubMed
  • 3. Kang CY, Chaudhry OO, Halabi WJ, Nguyen V, Carmichael JC, Stamos MJ, et al. Outcomes of laparoscopic colorectal surgery: data from the Nationwide Inpatient Sample 2009. Am J Surg 2012;204:952–7. ArticlePubMed
  • 4. Kang CY, Halabi WJ, Chaudhry OO, Nguyen V, Pigazzi A, Carmichael JC, et al. Risk factors for anastomotic leakage after anterior resection for rectal cancer. JAMA Surg 2013;148:65–71. ArticlePubMed
  • 5. Huang H, Guo Z, Li W, Zhang M, Li Y. A comparative study of using linear anastomosis with circular anastomosis in digestive tract reconstruction after laparoscopic radical total gastrectomy: a retrospective study. Medicine (Baltimore) 2023;102:e34588. ArticlePubMedPMC
  • 6. Lee H, Yoon YS, Kim YI, Park EJ, Kim MH, Lee JL, et al. The impact of powered circular staplers on anastomotic leak in left-sided colorectal cancer surgeries. Surg Endosc 2024;38:6111–9. ArticlePubMedPMCPDF
  • 7. Sun D, Zhang R, Wei M, Liu P, Zhong X, Liang Y, et al. Comparison between linear stapler and circular stapler after laparoscopic-assisted distal gastrectomy in patients with gastric cancer. Front Surg 2022;9:858236.ArticlePubMedPMC
  • 8. Keane C, Fearnhead NS, Bordeianou LG, Christensen P, Espin Basany E, Laurberg S, et al. International consensus definition of low anterior resection syndrome. ANZ J Surg 2020;90:300–7. ArticlePubMedPDF
  • 9. Cong J, Zhang H, Chen C. Definition and grading of anastomotic stricture/stenosis following low anastomosis after total mesorectal excision: a single-center study. Asian J Surg 2023;46:3722–6. ArticlePubMed
  • 10. Dindo D, Demartines N, Clavien PA. Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg 2004;240:205–13. ArticlePubMedPMC
  • 11. Whistance RN, Conroy T, Chie W, Costantini A, Sezer O, Koller M, et al. Clinical and psychometric validation of the EORTC QLQ-CR29 questionnaire module to assess health-related quality of life in patients with colorectal cancer. Eur J Cancer 2009;45:3017–26. ArticlePubMed
  • 12. Steger J, Jell A, Ficht S, Ostler D, Eblenkamp M, Mela P, et al. Systematic review and meta-analysis on colorectal anastomotic techniques. Ther Clin Risk Manag 2022;18:523–39. ArticlePubMedPMCPDF
  • 13. Hashempour MR, Moradi M, Oroomi RG, Daneshvar S, Meysamie A, Nikshoar M, et al. Assessing the role of anastomotic level in low anterior resection (LAR) surgery among rectal cancer patients in the development of LAR syndrome: a systematic review study. BMC Surg 2023;23:263.ArticlePubMedPMCPDF
  • 14. Sassun R, Sileo A, Ng JC, Mari G, Brucchi F, Ferrari D, et al. Low versus high ligation of inferior mesenteric artery in rectal and sigmoid cancers: a systematic review, meta-analysis, and trial sequential analysis of randomized controlled trials. Ann Surg Oncol 2026;33:210–9. ArticlePubMedPDF
  • 15. Yasuda K, Kawai K, Ishihara S, Murono K, Otani K, Nishikawa T, et al. Level of arterial ligation in sigmoid colon and rectal cancer surgery. World J Surg Oncol 2016;14:99.ArticlePubMedPMC
  • 16. Yin TC, Chen YC, Su WC, Chen PJ, Chang TK, Huang CW, et al. Low ligation plus high dissection versus high ligation of the inferior mesenteric artery in sigmoid colon and rectal cancer surgery: a meta-analysis. Front Oncol 2021;11:774782.ArticlePubMedPMC
  • 17. Habeeb TA, Mohammad H, Wasefy T, Mansour MI. Outcomes of side-to-end versus end-to-end colorectal anastomosis in nonemergent sigmoid and rectal cancers: a randomized controlled clinical trial. Ann Coloproctol 2023;39:231–41. ArticlePDF
  • 18. Wei M, Wang N, Yin Z, Wu T, Zhou S, Dang L, et al. Short-term and quality of life outcomes of patients using linear or circular stapling in esophagojejunostomy after laparoscopic total gastrectomy. J Gastrointest Surg 2021;25:1667–76. ArticlePubMedPDF
  • 19. Lee KY, Lee J, Park YY, Kim HJ, Oh ST. The effect of circular stapler size on anastomotic stricture formation in colorectal surgery: a propensity score matched study. PLoS One 2023;18:e0287595. ArticlePubMedPMC

Figure & Data

References

    Citations

    Citations to this article as recorded by  

      • Cite this Article
        Cite this Article
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Linear versus circular stapler for colorectal anastomosis in laparoscopic sigmoidectomy: a retrospective comparative study
        Ann Coloproctol. 2026;42(4):468-477.   Published online August 26, 2026
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      Related articles
      Linear versus circular stapler for colorectal anastomosis in laparoscopic sigmoidectomy: a retrospective comparative study
      Image Image Image
      Fig. 1. Step-by-step creation of an intracorporeal colorectal anastomosis using a linear stapler. (A) The proximal colon and rectal stump are aligned with an anchoring suture, and enterotomies are made on both sides. (B) An Endo GIA 60-mm linear stapler (Medtronic) is inserted through the enterotomies to create a side-to-side colorectal anastomosis. (C) The common enterotomy is closed with a continuous 3-0 Vicryl suture (Ethicon). (D) Anastomotic integrity is assessed by checking for air or fluid leakage.
      Fig. 2. Postoperative health-related quality of life (QoL) trajectories in the linear and circular stapler groups. The graph shows periodic changes in symptom scores across domains of the European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire–Colorectal Cancer (QLQ-CR29) questionnaire during the 12 months after surgery. Values are raw item scores on the 4-point Likert response scale (1, not at all; 4, very much). Higher scores indicate worse symptoms. Both groups showed initial postoperative worsening in QoL at 3 months, followed by improvement by 12 months. The linear stapler group showed faster recovery in selected domains, particularly bowel function and pain, than the circular stapler group during the early postoperative period. By 12 months, scores had converged between groups, with no significant difference in any QoL domain. (A) Abdominal pain. (B) Bloated feeling. (C) Blood and mucus in stool. (D) Stool frequency. (E) Fecal incontinence. (F) Embarrassed by defecation pattern. POM, postoperative month.
      Graphical abstract
      Linear versus circular stapler for colorectal anastomosis in laparoscopic sigmoidectomy: a retrospective comparative study
      Characteristic Linear stapler (n=23) Circular stapler (n=60) P-value
      Age (yr) 64.57±13.09 67.68±12.83 0.320
      Sex 0.792
       Male 15 (65.2) 42 (70.0)
       Female 8 (34.8) 18 (30.0)
      Body mass index (kg/m2) 21.23±2.25 21.56±1.87 0.870
      Comorbidity
       Diabetes 2 (8.7) 16 (26.7) 0.134
       Hypertension 8 (34.8) 20 (33.3) 0.901
      ASA physical status >0.999
       I 9 (39.1) 23 (38.3)
       II 11 (47.8) 27 (45.0)
       III 3 (13.1) 10 (16.7)
      Prior temporary colostomy 0 (0) 1 (1.7) >0.999
      Tumor distance from AV (cm) 25.87±2.78 23.28±5.15 0.530
      Tumor size (mm) 27.59±20.96 31.03±20.60 0.610
      Characteristic Linear stapler (n=23) Circular stapler (n=60) P-value
      Operative time (min) 90.73±14.02 94.63±13.65 0.250
      Operative blood loss (mL) 25 (15–40) 20 (15–30) 0.410
      Total No. of stapler cartridges used 3.04±0.82 1.53±0.72 <0.001
      No. of staplers for distal rectal transection 2.28±0.96 1.31±0.61 <0.001
      Cases by surgeons 0.953
       Surgeon 1 10 (43.5) 26 (43.3)
       Surgeon 2 7 (30.4) 20 (33.3)
       Surgeon 3 6 (26.1) 14 (23.3)
      Outcome Linear stapler (n=23) Circular stapler (n=60) P-value
      Advanced tumor stage (pT3–pT4) 21 (91.3) 51 (85.0) 0.719
      No. of lymph nodes harvested 7.45±2.96 8.65±4.92 0.310
      Lymph node staginga >0.999
       pN0 17 (73.9) 44 (74.6)
       pN1 4 (17.4) 10 (16.9)
       pN2 2 (8.7) 5 (8.5)
      Time to first flatus (day) 3.47±1.4 3.67±1.4 0.630
      Time to oral diet resumption (day) 4.32±1.49 3.93±1.73 0.350
      Length of hospital stay (day) 10.09±1.83 11.70±3.62 0.040
      Complication Linear stapler (n=23) Circular stapler (n=60) P-value
      Anastomotic leak 1 (4.3) 0 (0) 0.277
      Anastomotic bleeding 1 (4.3) 0 (0) 0.277
      Anastomotic stenosis 0 (0) 2 (3.3) >0.999
      Wound infection 0 (0) 1 (1.7) >0.999
      LARS 0 (0) 3 (5.0) 0.557
      Clavien-Dindo classificationa 0.413
       I 1 0
       II 1 2
      Domain Linear stapler Circular stapler U Z P-value Effect size (r)
      Urinary frequency 2 (2–3) 2 (2–4) 67.5 –0.45 0.622 0.09
      Urinary incontinence 1 (1–1) 1 (1–1) 72.0 –0.21 0.570 0.04
      Dysuria 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
      Abdominal pain 1 (1–1) 1 (1–1) 68.0 –0.42 0.380 0.08
      Buttock pain 1 (1–1) 1 (1–1) 68.0 –0.42 0.380 0.08
      Bloated feeling 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
      Blood and mucus in stool 2 (2–2) 2 (2–2) 81.5 0.29 0.559 0.06
      Dry mouth 1 (1–1) 1 (1–1.5) 64.5 –0.61 0.421 0.12
      Hair loss 1 (1–1) 1 (1–1) 69.5 –0.35 0.636 0.07
      Trouble with taste 1 (1–1.2) 1 (1–2) 69.0 –0.37 0.666 0.07
      Anxiety 1 (1–1.2) 1 (1–1.5) 72.0 –0.21 0.809 0.04
      Weight concerns 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
      Body image 3 (3–3) 3 (3–3) 72.0 –0.21 0.570 0.04
      Flatulence 1 (1–2) 1 (1–1.5) 83.0 0.37 0.665 0.07
      Fecal incontinence 1 (1–1) 1 (1–1) 72.0 –0.21 0.570 0.04
      Sore skin around anus 1 (1–1) 1 (1–1) 76.0 0 >0.999 0
      Stool frequency 2 (2–2) 2 (2–2) 72.0 –0.21 0.570 0.04
      Embarrassed by defecation pattern 1 (1–1) 1 (1–1) 72.0 –0.21 0.570 0.04
      Table 1. Patient characteristics (n=83)

      Values are presented as mean±standard deviation or number (%).

      ASA, American Society of Anesthesiologists; AV, anal verge.

      Table 2. Intraoperative characteristics (n=83)

      Values are presented as mean±standard deviation, median (interquartile range), or number (%).

      Table 3. Postoperative pathological and recovery outcomes (n=83)

      Values are presented as number (%) or mean±standard deviation.

      One missing case excluded in the circular stapler group.

      Table 4. Postoperative complications within 30 days (n=83)

      Values are presented as number (%) or number only. P-values were calculated using the 2-tailed Fisher exact test.

      LARS, low anterior resection syndrome.

      No severe complications (grade III–V) occurred in either cohort.

      Table 5. Quality of life at 12 months after laparoscopic sigmoidectomy

      Values are presented as median (interquartile range). Values are raw item scores on the 4-point Likert response scale (1 = not at all to 4 = very much); higher scores indicate worse symptoms in most domains.


      Ann Coloproctol : Annals of Coloproctology Twitter Facebook
      TOP